Shaanxi Ferrtx Enterprise Co.,Ltd.
Home> Company News> Isolated DC-DC Power Module: Safe for Medical Use?
Product Categories

Isolated DC-DC Power Module: Safe for Medical Use?

In life-critical medical systems, a single microamp of leakage current can prove fatal. Isolated DC-DC power modules serve as the frontline defense, but can compact designs truly meet stringent IEC 60601-1 standards? Here’s how cutting-edge isolation technology balances safety and miniaturization.

The Life-or-Death Math of Medical Isolation

Medical-grade isolation requires:

  • 2× Means of Patient Protection (2MOOP) at 4000VAC/10s

  • Patient leakage current <10μA

  • Creepage distances ≥8mm (per IEC 60601-1 Ed.3.1)

Leading modules like RECOM’s RMD-30 (32×20.5×10.2mm) achieve this via:

  • Triple-insulated wire Transformers with polyimide-silica hybrid encapsulation

  • 6kV reinforced isolation barriers using ceramic-filled polymers

  • Guard ring PCB layouts eliminating surface tracking

Shrinking Safeguards: Engineering Nano-Isolation

A. Material Innovations

  • Ferroxcube 3F45 cores reduce Transformer size by 40% vs. ferrite

  • AlN (aluminum nitride) substrates with 170 W/mK thermal conductivity

  • Parylene HT® conformal coating (<0.1% moisture absorption)

B. Topology Breakthroughs

  • Active clamp flyback (e.g., TDK’s CUS400M series) slashes size 60% vs. LLC resonant

  • Monolithic isolators (Silicon Labs Si86xx) replace optocouplers in 1.5mm²

C. Testing Protocol

  • 100% production HIPOT testing at 6kVDC

  • Partial discharge <3pC at 1.5× working voltage

Critical Applications Where Isolation Saves Lives

  • Ventilators: Murata’s MEJ1S0505SC (16.5×10.5×8mm) ensures <5μA leakage in oxygen sensors

  • Surgical Robots: KUKA’s LBR Med uses Vicor’s VI Chip® modules (22×17×7mm) with 5kVDC isolation for force feedback systems

  • Implantable Monitors: Abbott’s FreeStyle Libre 3 employs RECOM’s RP-1224 (11.6×6.1×4mm) achieving 4000VAC isolation in 0.3cm³

The Next Frontier: Smarter Protection

  • Self-monitoring isolation: TI’s AMC3330 integrates fault detection (ISO 13849 PL e)

  • GaN isolation: Efficient Power Conversion’s EPC23102 enables 5kV/ns CMTI in 3×5mm

  • 3D printed barriers: Nano-dimension dielectric inks creating 0.1mm insulation layers

Selection Checklist for Medical Designs

  1. Certification: EN 60601-1 3rd Ed + ANSI/AAMI ES60601-1

  2. MOOP Rating: Verify 2× protection minimum

  3. BF/CF Rating: Body-floating (BF) or cardiac-floating (CF) classification

  4. EMC Performance: Must pass IEC 61000-4-8 (20A/m immunity)

When patient safety hangs in the balance, only rigorously engineered isolated DC-DC power modules deliver uncompromised protection.

Request Medical Compliance Dossier:sales@ferrtx.com

July 27, 2025
Share to:

Let's get in touch.

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send